For a university lab's equipment ledger, the hardest part when we took over wasn't features — it was accounts.
How It Was Before
Forty-plus instruments spread across three rooms. The ledger system held 60-plus accounts — one per instructor, one per graduate student — with passwords stored locally as MD5. Students graduated, advisors moved groups; accounts were never deleted and passwords were forgotten. The admin's method was "whoever forgets gets a reset" — twenty-odd resets a semester.
Worse, some accounts were lent to outsiders — and when something went wrong, the logs pointed to no one.
Switching to LDAP
The university already had LDAP in place, with the student/staff ID as the unique identifier. Our changes were actually modest:
Login stopped querying the local users table; instead, the student/staff ID and password bind against LDAP, and on success the identity comes back via ou and group, mapped to the system's three roles: admin, supervising instructor, student. Locally we store only the ID, name, role, and last-login time — no passwords.
After this step, account creation and deletion belong to the university — deactivated on graduation, nothing to sync on our side. Password-reset tickets essentially disappeared.
One pitfall: our initial LDAP filter matched on cn, and two students shared a name — both bound successfully, but the wrong attributes came back. Switching to the unique uid fixed it.
Booking Conflicts
Another high-frequency problem in the ledger was equipment booking. The check for "is this slot taken" lived in the front end: two people opened the same day at the same time, both saw it free, both submitted successfully.
We added a unique index on (device_id, slot_start) to the bookings table — the database blocks duplicates directly, and the backend catches the conflict and returns "just booked by someone else." The front-end check remains, only to make the message arrive faster; we no longer trust it.
How the Inventory Gets Counted
Each instrument carries a QR code; scanning opens the detail page showing the custodian, last calibration date, and current status. During stocktaking the admin scans each one with a phone; the system records scan time and location, then exports an Excel. The first count covered 43 units — 3 of them marked "in use" in the ledger had actually moved to another room long ago.